{"id":11342,"date":"2026-10-03T02:03:01","date_gmt":"2026-10-03T00:03:01","guid":{"rendered":"https:\/\/gjergjihtextil.com\/matja-e-perdeve-hotel\/"},"modified":"2026-10-03T02:03:02","modified_gmt":"2026-10-03T00:03:02","slug":"matja-e-perdeve-hotel","status":"publish","type":"post","link":"https:\/\/gjergjihtextil.com\/it\/matja-e-perdeve-hotel\/","title":{"rendered":"Avoid Rework: Measure Hotel Curtains for Procurement (EN 13773)"},"content":{"rendered":"<\/p>\n<p>Measure curtains from the installed track, not from architectural plans. Capture width with overlap and returns, drop, and stack depth, then specify blackout, thermal, and heavy-duty fabric certified under EN 13773. Before any bulk production order, require a full-size mock-up and sign-off. Skip any of these four steps, and the risk of rework, delay, or a failed inspection rises sharply.<\/p>\n<hr>\n<blockquote>\n<p><strong>TL;DR:<\/strong><\/p>\n<ul>\n<li>Measure curtains from the installed track, not from plans, and record width with overlap, returns, and fabric stacking to ensure accuracy.<\/li>\n<li>Conduct a full-size mock-up to verify fabric fit, light leakage, and stacking before full production to avoid costly rework and delays.<\/li>\n<li>Require fire classification documentation, specifically EN 13773:2003, with batch-specific lab reports to ensure fabric safety and compliance.<\/li>\n<li>Use a detailed survey with three measurement points per dimension, photograph the site for cross-checking, and document obstructions and installation details.<\/li>\n<li>Choose fabric with proven durability, thermal insulation, and acoustic performance, and specify lab-tested rates for wash cycles, abrasion, and colorfastness.<\/li>\n<\/ul>\n<\/blockquote>\n<hr>\n<div data-blg-cta=\"after_tldr\" data-blg-cta-layout=\"split\" style=\"margin:28px 0;font-family:-apple-system, BlinkMacSystemFont, &apos;Segoe UI&apos;, Roboto, Helvetica, Arial, sans-serif\">\n<div style=\"border-radius:26px;padding:min(22px,3.2vw);background:radial-gradient(circle at 100% 0%,#d7dcea 0 150px,rgba(255,255,255,0) 151px),radial-gradient(circle at 0% 100%,#d7dcea 0 130px,rgba(255,255,255,0) 131px),linear-gradient(180deg,#e4e7f1 0%,#f2f3f8 100%)\">\n<div style=\"background:#ffffff;border-radius:18px;overflow:hidden\">\n<div style=\"display:flex;flex-wrap:wrap;background:linear-gradient(104deg,#112250 0%,#0b1634 33%,#ffffff 33.15%)\">\n<div style=\"flex:0 0 30%;min-width:150px;padding:30px 10px 30px 26px;color:#ffffff\">\n<div style=\"margin:0 0 14px\"><span style=\"display:inline-block;max-width:100%;border-radius:999px;padding:6px 13px;font-size:12px;font-weight:800;letter-spacing:0.1em;text-transform:uppercase;line-height:1.3;background:#ffffff;color:#152961\">Gjergjihtextil<\/span><\/div>\n<div style=\"font-size:12px;opacity:0.75\">gjergjihtextil.com<\/div>\n<\/div>\n<div style=\"flex:1 1 300px;padding:30px 28px 30px 40px\">\n<div style=\"font-size:23px;font-weight:800;line-height:1.2;letter-spacing:-0.01em;color:#1f2937;margin:0\">Plan Hotel Curtains With Confidence<\/div>\n<div style=\"width:56px;height:6px;border-radius:3px;background:#1e3a8a;margin:12px 0 14px\"><\/div>\n<div style=\"font-size:15px;line-height:1.55;color:#64748b;margin:0 0 22px\">Gjergji H Tekstil combines custom production, textile expertise, and hospitality supply experience for tailored curtain solutions.<\/div>\n<p><a href=\"https:\/\/gjergjihtextil.com\/it\/\" style=\"display:inline-flex;align-items:center;gap:9px;border-radius:10px;font-weight:700;font-size:15px;text-decoration:none;padding:13px 22px 13px 26px;background:#1e3a8a;color:#ffffff\">Explore hotel textile solutions<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h2 id=\"table-of-contents\" tabindex=\"-1\">Table of Contents<\/h2>\n<ul>\n<li><a href=\"#essential-measurement-checklist-for-every-room-survey\">Essential measurement checklist for every room survey<\/a><\/li>\n<li><a href=\"#fabric-and-performance-requirements-for-hotels\">Fabric and performance requirements for hotels<\/a><\/li>\n<li><a href=\"#fire-safety-and-standards-to-require-in-specifications\">Fire safety and standards to require in specifications<\/a><\/li>\n<li><a href=\"#step-by-step-field-measuring-procedure-for-procurement-teams-and-installers\">Step-by-step field measuring procedure for procurement teams and installers<\/a><\/li>\n<li><a href=\"#mock-up-installation-qa-and-acceptance-checklist\">Mock-up, installation QA, and acceptance checklist<\/a><\/li>\n<li><a href=\"#manufacturer-perspective-procurement-failures-and-practical-safeguards\">Manufacturer perspective: procurement failures and practical safeguards<\/a><\/li>\n<li><a href=\"#how-gjergji-h-tekstil-supports-hotel-procurement\">How Gjergji H Tekstil supports hotel procurement<\/a><\/li>\n<li><a href=\"#sources\">Sources<\/a><\/li>\n<li><a href=\"#faq\">FAQ<\/a><\/li>\n<\/ul>\n<h2 id=\"essential-measurement-checklist-for-every-room-survey\" tabindex=\"-1\">Essential measurement checklist for every room survey<\/h2>\n<p>A room survey is where most hotel curtain projects succeed or fail. The underlying rule is simple: trust the installed track, not the drawing set. Architectural plans change during construction, and a track that shifts by even a few centimeters will throw off every curtain ordered against the original plan.<\/p>\n<p>Once the track is fixed in place, record the following for each window:<\/p>\n<ul>\n<li>Track length from start bracket to end bracket, not wall-to-wall distance.<\/li>\n<li>Curtain drop, measured from the track or rail down to the finished floor, accounting for carpet thickness or raised flooring.<\/li>\n<li>Total width of fabric needed, including the center overlap and the returns that wrap the fabric back to the wall.<\/li>\n<li>Stack depth: the space the curtain occupies when fully drawn open, which determines whether it clears windows, moldings, or adjacent fixtures.<\/li>\n<li>Obstructions near the track, including radiators, deep sills, trim profiles, or motor housings for automated systems.<\/li>\n<\/ul>\n<p>Each measurement needs a clear label: room number, window type, and handedness (left or right draw), so the production team never has to guess which number belongs to which window. A spreadsheet with one row per window, rather than a narrative description, keeps this organized across dozens or hundreds of rooms.<\/p>\n<p>Environmental context matters just as much as dimensions. A west-facing room with heavy afternoon sun calls for different fabric weight and lining than a courtyard-facing room shielded from direct light. Rooms near elevators, service corridors, or street-facing facades benefit from fabric chosen with acoustic performance in mind, which later sections cover in detail.<\/p>\n<p><strong>Pro Tip:<\/strong> <em>Photograph every window with a tape measure or laser visible in the frame, so the production team can cross-check a disputed figure without a second site visit.<\/em><\/p>\n<p>Skipping any of these fields on the survey form is the single most common reason a hotel curtain order needs remaking after delivery.<\/p>\n<h2 id=\"fabric-and-performance-requirements-for-hotels\" tabindex=\"-1\">Fabric and performance requirements for hotels<\/h2>\n<p>Hotel curtains carry more operational weight than curtains in a private home. They control light for sleep, hold heat in winter and keep it out in summer, dampen noise from corridors and streets, and survive industrial laundering cycle after cycle. Specifying fabric on appearance alone is how procurement teams end up reordering within two years.<\/p>\n<p>Blackout fabric is the default for guest bedrooms, since even small amounts of ambient light affect guest sleep quality and online review scores. Dimout fabric, which blocks most but not all light, suits lounges, meeting rooms, or spaces where some natural light is wanted during the day. The lining matters as much as the face fabric: a dense, tightly woven lining adds both blackout performance and a measurable improvement in thermal insulation, which can ease the load on HVAC systems in rooms with large glazed facades.<\/p>\n<p>Acoustic performance comes from mass and construction rather than color or print. Heavier fabric composites, especially when paired with a thermal lining and installed with minimal gaps at the track and floor, reduce sound transfer from outside or adjoining corridors.<\/p>\n<p>Durability should be requested as data, not assumed from a swatch. Ask suppliers for:<\/p>\n<ul>\n<li>Rated wash cycle count for industrial laundering, since hotel curtains launder far more often than residential textiles.<\/li>\n<li>Martindale abrasion rating, which measures resistance to wear from handling and repeated opening and closing.<\/li>\n<li>Colorfastness rating, so fabric does not fade unevenly under sun exposure or repeated washing.<\/li>\n<\/ul>\n<p><strong><a href=\"https:\/\/standards.iteh.ai\/catalog\/standards\/cen\/9b8d627c-4715-44c5-aa51-f8bed42a5acf\/en-13773-2003\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">EN 13773:2003<\/a> sets the classification scheme for how vertically hung curtain fabrics behave when exposed to flame<\/strong>, and that classification should appear on every lab report a supplier submits with a fabric sample.<\/p>\n<p>Build these fields directly into the RFQ: required lab test references, the wash cycle rating claimed, and a retained physical sample for comparison against the delivered batch. A supplier unwilling to retain a sample against future batches is one to question closely.<\/p>\n<h2 id=\"fire-safety-and-standards-to-require-in-specifications\" tabindex=\"-1\">Fire safety and standards to require in specifications<\/h2>\n<p>Fire classification is not optional paperwork. It is the test that determines whether a fabric is legally and practically acceptable for use in guest-occupied spaces. EN 13773:2003 specifies a classification scheme for the burning behaviour of vertically oriented fabrics intended for curtains and drapes, and it is the reference manufacturers and certification bodies use to assess how a curtain fabric ignites and how flame spreads across it.<\/p>\n<p>Procurement should build the following into every specification:<\/p>\n<ul>\n<li>Require EN 13773:2003 classification, or the locally accepted equivalent test report, before accepting any fabric for guest rooms.<\/li>\n<li>Request a batch-specific lab report and certificate delivered alongside the physical shipment, not a generic manufacturer datasheet.<\/li>\n<li>Include clause language stating that any fabric delivered without matching batch documentation will be held at receiving until a report is supplied.<\/li>\n<\/ul>\n<table>\n<thead>\n<tr>\n<th>Specification element<\/th>\n<th>What to request<\/th>\n<th>Why it matters<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Fire classification<\/td>\n<td>EN 13773:2003 test report<\/td>\n<td>Confirms burning behaviour is documented and traceable<\/td>\n<\/tr>\n<tr>\n<td>Batch traceability<\/td>\n<td>Certificate tied to delivered lot<\/td>\n<td>Prevents unverified substitutions mid-order<\/td>\n<\/tr>\n<tr>\n<td>Pre-production testing<\/td>\n<td>Lab report before cutting<\/td>\n<td>Avoids producing full runs of non-compliant fabric<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>When a fabric lacks a current test report, the correct response is to pause, not proceed. Require pre-production testing on a representative sample and delay final acceptance until the report confirms the classification claimed in the quote.<\/p>\n<h2 id=\"step-by-step-field-measuring-procedure-for-procurement-teams-and-installers\" tabindex=\"-1\">Step-by-step field measuring procedure for procurement teams and installers<\/h2>\n<p>Timing decides accuracy. Measure after the track or rail is physically installed, never from a drawing, since even a well-built track rarely lands exactly where the plan shows it. When a renovation schedule forces measurement before the track exists, use the finished wall and ceiling lines as the reference and flag every figure as provisional until an installer confirms it on-site.<\/p>\n<p>Bring a laser measure, a spirit level, a camera for scaled photos, and a standardized RFQ spreadsheet into every room.<\/p>\n<ol>\n<li>Measure width at three points along the track: left end, center, right end, to catch any bow or misalignment in the rail.<\/li>\n<li>Measure drop at three points across the window: left, center, right, since floors and ceilings are rarely perfectly level.<\/li>\n<li>Note every obstruction (sills, radiators, trim, motor housing) directly on the spreadsheet row for that window.<\/li>\n<li>Record the mounting type, bracket projection, and whether the installation is ceiling-fixed or wall-fixed.<\/li>\n<li>Calculate total cloth width by adding the track length, the overlap, and both returns. A track measuring 300 centimeters with a 10-centimeter center overlap and two 8-centimeter returns needs 326 centimeters of finished width before fabric fullness is applied.<\/li>\n<li>Apply the fullness ratio the heading style requires, then round up to the nearest fabric increment the mill supplies.<\/li>\n<\/ol>\n<p><strong>Pro Tip:<\/strong> <em>Keep a running duplicate check: have a second team member re-measure one in every ten windows and compare figures before the spreadsheet goes to production.<\/em><\/p>\n<p>Quality control at this stage is cheap. A duplicate measurement that catches a transposed number now costs minutes; the same error caught at delivery costs a remake and a delayed opening.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/media.babylovegrowth.ai\/blog-images\/organization-24860\/1790851169491_Step-by-step-field-measuring-procedure-for-procurement-teams-and-installers-overview-diagram.jpeg\" alt=\"Step-by-step field measuring procedure for procurement teams and installers \u2014 overview diagram\"><\/p>\n<h2 id=\"mock-up-installation-qa-and-acceptance-checklist\" tabindex=\"-1\">Mock-up, installation QA, and acceptance checklist<\/h2>\n<p>A mock-up tells procurement whether the specification actually works in the room, not just on paper. Fabric that reads correctly on a swatch can still hang short, stack too deep, or leak light at the edges once it is on the track.<\/p>\n<p>Before authorizing bulk production, check the mock-up against this list:<\/p>\n<ul>\n<li>Floor clearance matches the intended drop with no dragging or excessive gap.<\/li>\n<li>Stack depth clears any adjacent window, wall return, or furniture placement.<\/li>\n<li>No light leakage at the top track, side returns, or center overlap when fully closed.<\/li>\n<li>Overlap closes fully without gapping when both panels meet.<\/li>\n<li>For motorized systems, motor travel limits stop the panel at the correct open and closed positions.<\/li>\n<\/ul>\n<p>Sign-off should be a documented step, not a verbal approval. If a check fails, the corrective action and the retest date go on record before the order proceeds. Decide early who produces the mock-up, who absorbs the cost, and how far in advance of the full order it needs to be built and approved.<\/p>\n<h2 id=\"manufacturer-perspective-procurement-failures-and-practical-safeguards\" tabindex=\"-1\">Manufacturer perspective: procurement failures and practical safeguards<\/h2>\n<p>Decades of supplying hotel textiles across the region have shown the same mistakes recur: measuring before the track is fixed, forgetting returns in the width calculation, and skipping the mock-up to save a week on the schedule. Each shortcut tends to resurface later as a remake, a delayed room block, or a guest-facing defect. The safeguard is procedural, not clever: field-measure after installation, require fire-class documentation on every batch, and treat the mock-up as a contractual checkpoint rather than a courtesy.<\/p>\n<blockquote>\n<p><em>\u2014 Xpert<\/em><\/p>\n<\/blockquote>\n<h2 id=\"how-gjergji-h-tekstil-supports-hotel-procurement\" tabindex=\"-1\">How Gjergji H Tekstil supports hotel procurement<\/h2>\n<p>Thirty years of supplying hospitality textiles across international hotel brand standards means a supply chain built to handle exactly this kind of specification work, not just a catalog to browse. Gjergji H Tekstil supports procurement teams with site surveys, custom manufacturing, industrial-wash-grade fabrics, testing and certification documentation, and full mock-up services before any bulk run begins.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/csuxjmfbwmkxiegfpljm.supabase.co\/storage\/v1\/object\/public\/blog-images\/organization-24860\/1775118470908_gjergjihtextil.jpg\" alt=\"Gjergjihtextil\"><\/p>\n<ul>\n<li>Request a site survey or send a room-by-room spreadsheet directly for quoting.<\/li>\n<li>Receive fabric samples with batch-level test documentation attached.<\/li>\n<li>Get a full-size mock-up built and reviewed before production starts.<\/li>\n<\/ul>\n<p>Procurement teams ready to move forward can start with the <a href=\"https:\/\/gjergjihtextil.com\/it\/tekstile-per-hotel-dhe-airbnb\/\" target=\"_blank\" rel=\"noopener\">Tekstile p\u00ebr Hotel &amp; AirBnB<\/a> page to request a site survey or submit specifications directly.<\/p>\n<h2 id=\"faq\" tabindex=\"-1\">FAQ<\/h2>\n<h3 id=\"what-is-the-correct-way-to-measure-hotel-curtains\" tabindex=\"-1\">What is the correct way to measure hotel curtains?<\/h3>\n<p>Measure from the installed track or rail, not from architectural drawings, capturing width with overlap and returns, drop to the finished floor, and stack depth. Record three width points and three drop points per window to catch any variation in the track or floor line.<\/p>\n<h3 id=\"why-does-track-installation-timing-matter-for-curtain-measurement\" tabindex=\"-1\">Why does track installation timing matter for curtain measurement?<\/h3>\n<p>Tracks rarely land exactly where the drawing shows them, so measuring before installation risks ordering the wrong size. Waiting until the track is physically fixed in place removes that guesswork entirely.<\/p>\n<h3 id=\"what-fire-safety-standard-applies-to-hotel-curtain-fabric\" tabindex=\"-1\">What fire safety standard applies to hotel curtain fabric?<\/h3>\n<p>EN 13773:2003 specifies a classification scheme for the burning behaviour of vertically oriented curtain and drape fabrics, and procurement should request this classification along with a batch-specific lab report before accepting delivery.<\/p>\n<h3 id=\"why-is-a-mock-up-necessary-before-placing-a-bulk-curtain-order\" tabindex=\"-1\">Why is a mock-up necessary before placing a bulk curtain order?<\/h3>\n<p>A mock-up confirms the specification works in the actual room, checking floor clearance, stack depth, light leakage, and overlap closure before committing to full production. Catching a problem at the mock-up stage avoids the cost and delay of remaking an entire order.<\/p>\n<h3 id=\"does-gjergji-h-tekstil-provide-testing-and-mock-up-services-for-hotel-curtains\" tabindex=\"-1\">Does Gjergji H Tekstil provide testing and mock-up services for hotel curtains?<\/h3>\n<p>Yes, some suppliers support hotel procurement with site surveys, custom manufacturing, fabric testing and certification documentation, and full-size mock-ups before bulk production, drawing on supply-chain control built over many years of hospitality textile work.<\/p>\n<h2 id=\"recommended\" tabindex=\"-1\">Recommended<\/h2>\n<ul>\n<li><a href=\"https:\/\/gjergjihtextil.com\/en\/valezimi-i-perdeve-hotel\" target=\"_blank\" rel=\"noopener\">Choosing the Right Wave System for Hotel Curtains<\/a><\/li>\n<li><a href=\"https:\/\/gjergjihtextil.com\/en\/curtain-types-for-hotels\" target=\"_blank\" rel=\"noopener\">Best Curtain Types for Hotels: A Specification Guide<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Procurement checklist: measure from the installed track, insist on EN 13773 reports, and require a mock up before production to prevent costly curtain rework.<\/p>","protected":false},"author":1,"featured_media":11344,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[21],"tags":[],"class_list":["post-11342","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news"],"_links":{"self":[{"href":"https:\/\/gjergjihtextil.com\/it\/wp-json\/wp\/v2\/posts\/11342","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gjergjihtextil.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gjergjihtextil.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gjergjihtextil.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gjergjihtextil.com\/it\/wp-json\/wp\/v2\/comments?post=11342"}],"version-history":[{"count":1,"href":"https:\/\/gjergjihtextil.com\/it\/wp-json\/wp\/v2\/posts\/11342\/revisions"}],"predecessor-version":[{"id":11343,"href":"https:\/\/gjergjihtextil.com\/it\/wp-json\/wp\/v2\/posts\/11342\/revisions\/11343"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gjergjihtextil.com\/it\/wp-json\/wp\/v2\/media\/11344"}],"wp:attachment":[{"href":"https:\/\/gjergjihtextil.com\/it\/wp-json\/wp\/v2\/media?parent=11342"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gjergjihtextil.com\/it\/wp-json\/wp\/v2\/categories?post=11342"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gjergjihtextil.com\/it\/wp-json\/wp\/v2\/tags?post=11342"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}